Incidence, Treatment, and Outcomes of Symptomatic Device Lead-Related Venous Obstruction.

Ferro, Enrico G, Daniel B Kramer, Siling Li, Andrew H Locke, Shantum Misra, Alec A Schmaier, Brett J Carroll, et al. 2023. “Incidence, Treatment, and Outcomes Of Symptomatic Device Lead-Related Venous Obstruction.”. Journal of the American College of Cardiology 81 (24): 2328-40.

Abstract

BACKGROUND: The incidence and clinical impact of lead-related venous obstruction (LRVO) among patients with cardiovascular implantable electronic devices (CIEDs) is poorly defined.

OBJECTIVES: The objectives of this study were to determine the incidence of symptomatic LRVO after CIED implant; describe patterns in CIED extraction and revascularization; and quantify LRVO-related health care utilization based on each type of intervention.

METHODS: LRVO status was defined among Medicare beneficiaries after CIED implant from October 1, 2015, to December 31, 2020. Cumulative incidence functions of LRVO were estimated by Fine-Gray methods. LRVO predictors were identified using Cox regression. Incidence rates for LRVO-related health care visits were calculated with Poisson models.

RESULTS: Among 649,524 patients who underwent CIED implant, 28,214 developed LRVO, with 5.0% cumulative incidence at maximum follow-up of 5.2 years. Independent predictors of LRVO included CIEDs with >1 lead (HR: 1.09; 95% CI: 1.07-1.15), chronic kidney disease (HR: 1.17; 95% CI: 1.14-1.20), and malignancies (HR: 1.23; 95% CI: 1.20-1.27). Most patients with LRVO (85.2%) were managed conservatively. Among 4,186 (14.8%) patients undergoing intervention, 74.0% underwent CIED extraction and 26.0% percutaneous revascularization. Notably, 90% of the patients did not receive another CIED after extraction, with low use (2.2%) of leadless pacemakers. In adjusted models, extraction was associated with significant reductions in LRVO-related health care utilization (adjusted rate ratio: 0.58; 95% CI: 0.52-0.66) compared with conservative management.

CONCLUSIONS: In a large nationwide sample, the incidence of LRVO was substantial, affecting 1 of every 20 patients with CIEDs. Device extraction was the most common intervention and was associated with long-term reduction in recurrent health care utilization.